SiAF332111E
5.41 Inverter Circuit Abnormality
Applicable
All outdoor unit models
Models
L1
Error Code
Method of Error
Error is detected based on the current value during waveform output before starting
Detection
compressor.
Error is detected based on the value from current sensor during synchronous operation when
starting the unit.
Error Decision
Overcurrent flows during waveform output.
Conditions
Error of current sensor during synchronous operation.
IPM failure.
Supposed
IPM failure
Causes
Current sensor failure
Drive circuit failure
Part 6 Service Diagnosis
Troubleshooting by Error Code
265