GRT655/655L OPERATOR MANUAL
When any crane function is being commanded from
approximately 0 to 15% of controller input, the software
will increase the throttle command from idle to a
predetermined throttle command defined by the
operator.
When all crane functions are not being commanded for
approximately 3 seconds, the ECO mode software will
reduce the throttle to idle.
Terminology
Term
ECO mode is OFF (throttle
Disabled ECO Mode
command percent is always 0%
in this mode)
ECO mode is ON and can be
Enabled ECO mode
operated at commanded throttle
percentage
ECO mode has commanded a
throttle percent greater than 0%
Active ECO mode
(Must be enabled to become
active)
ECO mode is enabled and the
Inactive ECO mode
command throttle percentage is
0%
The throttle percentage set by
Throttle Setpoint
crane operator by pressing the
(Setpoint)
Increment/Decrement Switch in
the superstructure cab.
Requirements
ECO mode can be enabled by the crane operator on the
Operating Display Module (ODM). The default is for ECO
mode to be disabled when shipped from the factory. Once
enabled, the system stays enabled until disabled through the
ODM.
NOTE:
ECO
mode
stays
independent of ignition key cycles and disconnect
switch cycles.
The ODM screen that is used to enable ECO mode must
contain the following information:
Actual throttle command to the engine
ECO mode Throttle percent setpoint
ECO mode status (enabled, disabled, active, and
inactive)
When enabled the throttle setpoint will be set to the ECO
mode Throttle percent setpoint unless the operator has
previously set it to a higher value using the Increment /
Decrement switch.
The operator can increase the throttle command using the
throttle pedal independent if ECO mode is active or inactive.
Grove
Definition
disabled
(or
enabled)
Published 3-23-2020, Control # 654-04
OPERATING PROCEDURES
ECO mode is forced to inactive when the crane transmission
is being shifted to Forward or Reverse, or all crane functions
are disabled.
When active, ECO mode will ramp the throttle percent from 0
to setpoint when any crane function command goes above
5% command. Once ECO mode output is at the setpoint, the
output will stay at the setpoint until no crane functions are
being commanded for 3 seconds. Then the ECO mode
throttle command is to be set to 0% (step down).
NOTE:
Ramp time for increasing throttle percent is
2 seconds from 0% to 100% throttle (slope = 50%
per second).
Operation
Crane is able to idle at 700 RPM when crane functions
are not enabled.
Crane idles at 950 RPM when any crane function has
been enabled.
Operating Display menu allows operator to turn on "ECO
Mode" and set the operating engine speed for the crane.
When operator turns ECO mode ON:
-
Crane ramps engine from idle to operating speed
using the first 15% of the controller movement to
control the ramp.
-
Crane maintains operating RPM while crane
functions are active and for a period of 3 seconds
after crane functions go inactive.
-
Crane ramps engine speed back down to idle point.
Benefits
Less
noise
and
less
maintaining crane at fixed "operating speed".
Set point for engine operating speed is easily changed
by the operator.
Operator can command additional engine speed at any
time using the accelerator pedal.

Information Group

The Information Group is made up of the following function
icons (Figure 4-59):
Operating Hours icon
(refer to Viewing the Operating Hours, page 4-91)
Engine Fault Code icon
(refer to Viewing the Engine Fault Codes, page 4-92)
Crane Fault Code icon
(refer to Viewing the Crane Fault Codes, page 4-93)
Software Revision icon
(refer to Viewing the Software Revisions, page 4-93)
fuel
consumption
versus
4-89