Cisco 3000 Use & Care Manual page 138

Cisco systems network device assembly guide
Table of Contents

Advertisement

Power Requirements for the Cisco TelePresence 3000
Use care when you route the power cables from the PDUs. Do not bend the cables immediately after they
Caution
exit the PDUs and be sure that the cable does not pull on, or cause any strain to, the PDU socket and
power cord plug connection. Incorrectly routed cables can cause undue stress to the PDU receptacle and
the power cord plug.
Overcurrent protection is provided by branch circuit protection rated 20A @ 100-120 volts.
Warning
Warning
Output receptacles cannot exceed 15A @ 100-120 volts for any one receptacle.
Power Requirements for the Cisco TelePresence 3000
Table 8-1
Caution
Correct routing of the various power cords to the PDUs and auxiliary control unit is critical for the safety
and success of the Cisco TelePresence 3000. Route each power unit to a different 20 amp circuit to
prevent circuit overload when all the electrical components are properly installed.
Table 8-1
PDU and Auxiliary Control Unit Locations and Power Requirements
Left PDU 1
(Located on Left Accessory Cabinet)
Left PDU 2
(Located on Left Accessory Cabinet)
Right PDU
(Located on Right Accessory Cabinet)
Auxiliary Control Unit
(Located on rear of display structure)
Table PDU
(Located above the projector under the Center table segment)
Attach the left Power Distribution Unit (PDU) to the left Accessory cabinet and connect the power cord
Step 1
for the PDU into the power outlet.
The accessory cabinets each have screw holes for two PDUs on one side wall and screw holes for one
PDU on the other. When the cabinets are correctly oriented with each door opening out to the side, the
right cabinet has the single-PDU side facing the rear wall, and the left cabinet has the double set of holes
facing the rear wall.
Cisco TelePresence System 3000
8-2
provides the power requirements and PDU locations for the Cisco TelePresence 3000 system.
Chapter 8
Routing Power and Signal Cables
AC wall outlet
20 amps @100-120volts
or 10 amps @ 230-240 volts
AC wall outlet
20 amps @100-120volts
or 10 amps @ 230-240 volts
AC wall outlet
20 amps @100-120volts
or 10 amps @ 230-240 volts
AC wall outlet
20 amps @100-120volts
or 10 amps @ 230-240 volts
AC wall outlet
20 amps @100-120volts
or 10 amps @ 230-240 volts
OL-14521-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Telepresence 3000

Table of Contents