Fault A09
Position the function selector to
to the required position
(summer mode) or
the reset attempts do not reactivate the boiler, request the intervention
of the Technical Assistance Service.
Fault A09
The boiler is equipped with an auto-diagnostic system which, based
on the total number of hours in certain operating conditions, can signal
the need to clean the primary exchanger (alarm code 09 and flue gas
meter >2,500).
Once the cleaning operation has been completed, using the special kit
supplied as an accessory, the total hour meter will need to be reset to
zero as follows:
- switch off the power supply
- remove the shell
- turning the instrument panel towards you
- unscrew the two screws of the small cover on the electronic board to
have access to the terminals
BOILER STATUS
Off status (OFF)
Stand-by
ACF alarm lockout module
ACF electronics fault alarm
25 C.S.I. - 30 C.S.I./R.S.I.: fumes exhaust - air intake obstruction alarm
Limit thermostat alarm
Tacho fan alarm
20 R.S.I.: air pressure switch alarm
Water pressure switch alarm
NTC domestic water fault (R.S.I. only with external water tank with probe)
NTC heating delivery fault
Heating delivery probe over-temperature
Delivery/return line probe differential alarm
NTC heating return line fault
20 R.S.I.: low temperature system thermostat alarm
Heating return line probe over-temperature
Outlet/return line probe differential alarm
Cleaning the primary heat exchanger
NTC flue gases fault
Flue gases probe over-temperature
Parasite flame
25 C.S.I. - 30 C.S.I./R.S.I.: low temperature system thermostat alarm
Temporary pending ignition
Water pressure switch intervention
Calibration service
Calibration installer
Chimney sweep
Vent cycle
Pre-heating enabled (only C.S.I.)
Preheating heat request (only C.S.I.)
External probe presence
Domestic water heat request
Heating heat request
Antifreeze heat request
Flame present
(OFF), wait 5-6 seconds then set it
(winter mode). If
- while the boiler is powered up, using a small screwdriver included,
press the CO button (fig. 42) for at least 4 seconds, to check the
meter has been reset, power down then power up the boiler; the
meter reading is shown on the monitor after the "-C-" sign.
b
Live electrical parts.
Note: the meter resetting procedure should be carried out after each
indepth cleaning of the primary exchanger or if this latter is replaced.
To check the status of the total hour meter, multiply the reading by 100
(e.g. reading of 18 = 1,800 total hours; reading of 1 = 100 total hours).
The boiler continues to operate normally even when the alarm is
activated.
DISPLAY
OFF
-
A01
A02
A03
A04
A06
A07
A08
A09
A11
A77
80°C flashing
flashing
ADJ
ACO
flashing
60°C
80°C
Mynute Green E C.S.I. - R.S.I.
TYPES OF ALARMS
None
Signal
Definitive lockout
Definitive lockout
Definitive lockout
Definitive lockout
Signal
Temporary stop
Temporary then definitive
Definitive lockout
Temporary stop
Temporary stop
Temporary then definitive
Definitive lockout
Signal
Temporary stop
Temporary then definitive
Temporary stop
Temporary stop
Temporary stop
Temporary stop
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
Signal
17

Advertisement

loading