MULTIGAS TABLE
DESCRIPTION
Lower Wobbe index (at 15°C-1013 mbar)
Net Calorific Value
Supply nominal pressure
Supply minimum pressure
Mynute Green E 25 C.S.I.
Burner: number of nozzles - diameter of nozzles - lenght
Diaphragm: number of holes - diameter of holes
CH maximum gas capacity
DHW maximum gas capacity
CH/DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions (CH)
Maximum number of fan revolutions (DHW)
Minimum number of fan revolutions (CH)
Minimum number of fan revolutions (DHW)
Mynute Green E 30 C.S.I.
Burner: number of nozzles - diameter of nozzles - lenght
Diaphragm: number of holes - diameter of holes
CH maximum gas capacity
DHW maximum gas capacity
CH/DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions (CH)
Maximum number of fan revolutions (DHW)
Minimum number of fan revolutions (CH)
Minimum number of fan revolutions (DHW)
Mynute Green E 20 R.S.I.
Burner: number of nozzles - diameter of nozzles - lenght
Diaphragm: number of holes - diameter of holes
CH/DHW maximum gas capacity
CH/DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions (CH/DHW)
Minimum number of fan revolutions (CH/DHW)
Mynute Green E 30 R.S.I.
Burner: number of nozzles - diameter of nozzles - lenght
Diaphragm: number of holes - diameter of holes
CH maximum gas capacity
DHW maximum gas capacity
CH/DHW minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions (CH)
Maximum number of fan revolutions (DHW)
Minimum number of fan revolutions (CH)
Minimum number of fan revolutions (DHW)
The data indicated must not be used to certify the system; for certification, use the data indicated in the "System handbook" measured during first
ignition. All the pressure values are measured with the compensation socket disconnected.
20
Methane gas (G20)
MJ/m
S
3
MJ/m
S
3
MJ/KgS
mbar (mm W.C.)
20 (203,9)
mbar (mm W.C.)
10 (102,0)
n° - mm - mm
1 - 63 - 110
n° - mm
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
rpm/min
rpm/min
rpm/min
rpm/min
rpm/min
n° - mm - mm
1 - 63 - 110
n° - mm
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
rpm/min
rpm/min
rpm/min
rpm/min
rpm/min
n° - mm - mm
1 - 63 - 95
n° - mm
1x4,7 flap + 1x4,2 free
Sm
/h
3
kg/h
Sm
/h
3
kg/h
rpm/min
rpm/min
rpm/min
n° - mm - mm
1 - 63 - 110
n° - mm
Sm
/h
3
kg/h
Sm
/h
3
kg/h
Sm
/h
3
kg/h
rpm/min
rpm/min
rpm/min
rpm/min
rpm/min
Propane (G31)
45,67
70,69
34,02
88
-
46,34
37 (377,3)
1 - 63 - 110
1 - 6
1 - 4,6
2,12
1,55
2,64
1,94
0,63
0,47
3.300
3.300
4.100
4.100
4.900
4.900
1.500
1.400
1.500
1.400
1 - 63 - 110
1 - 6
1 - 4,6
2,64
1,94
3,17
2,33
0,63
0,47
3.300
3.300
4.900
4.900
5.800
5.800
1.500
1.400
1.500
1.400
1 - 63 - 95
1x3,4 flap + 1x3,25 free
2,12
1,55
0,30
0,31
3.700
3.700
4.500
4.500
1.200
1.500
1 - 63 - 110
1 - 6
1 - 4,6
2,64
1,94
3,17
2,33
0,63
0,47
3.300
3.300
4.900
4.900
5.800
5.800
1.500
1.400
1.500
1.400
-