31 March, 1997
BIT SWITCH 1
Bit
Function
Default resolution
0
setting
0: Standard
1: Fine
Date format
1
0: Day/Month/Year
1: Month/Day/Year
Default scan density setting
2
Same as the Function 47 (Density) setting.
3
0
 =
Normal
,
0
System initialization
4
0: Disabled
1: Enabled
Modem rate fall back
when a negative post
5
message is received
0: Disabled
1: Enabled
6
Not used.
Tx/Rx counter reset
7
0: Disabled
1: Enabled
Same as the Function 47 (Resolution) setting.
This bit determines the default resolution setting.
Changes the date format as shown.
1
0
1
 =
 =
Dark
,
Light
0
1
1
Refer to section 4.2.13, SYSTEM INITIALIZATION.
0: The machine will send the next page at the same
modem rate as used in the previous error page. (In
memory transmission, an error page is re-transmitted.)
1: The machine will use a lower modem rate for the next
page.
Do not change the factory setting.
If this bit set to 1, then transmission and reception
counters are reset to 0.
This bit automatically resets to 0 after counter reset.