BIT SWITCHES

4.3 BIT SWITCHES
BIT SWITCH 0
Bit
Function
0
ADF test mode
0: Disabled
1: Enabled
1
Remote Diagnostics
0: Not acceptable
1: Acceptable
2
Not used
3
Not used
4
I/O rate (Tx)
0: 10 ms
1: 20 ms
5
Not used
6
Password display
0: Disabled
1: Enabled
7
Limit tx
0: Disabled
1: Enabled
Change this bit to 1 to test the ADF mechanism. Always
reset this switch to 0 (zero) after the test.
To start the test, place a document in the ADF and
press the Start key. The machine feeds the document
until the Stop key is pressed.
0: The machine disconnects the line if a RDS accesses
the machine for diagnostics.
The default setting is "1".
Do not change the setting.
Do not change the setting.
This bit determines the I/O rate used in non-ECM
transmission.
This setting is available in NSS/NSF mode only.
Do not change the factory setting.
If the customer forgets the password for the "Limit Tx"
function, change this bit to 1.
The current password will be displayed when Function
23 is selected.
This bit will automatically reset to 0 after using Function
23.
Same as the function 47 (Limit Tx) setting.
1: Transmission is not possible unless the programmed
password is typed in.
4-8