External Unit Electrical Connections - Ariston NIMBUS HYBRID MODULE UNIVERSAL NET Manual

Hide thumbs Also See for NIMBUS HYBRID MODULE UNIVERSAL NET:
Table of Contents

Advertisement

Available languages

Available languages

Warning
Electric shocks can cause serious injuries and even death. The electrical connections must be made by qualifi ed technical
personnel. Carry out grounding before proceeding with other electrical connections.

External unit electrical connections

The electrical panel of the outdoor unit is located at the front of the form, after removing the front panel.
The power cable can be connected to the terminal block shown in the fi gure, using a core hitch. If the hole on the unit is not
large enough, make it bigger.
Check that the fastening of the power supply cable and the connecting cable between HYBRID MODULE and external unit are
properly secured using a cable locking device, freely commercially available, in order to ensure that no contact occurs between
the cables and hot piping. This block must also ensure good tensile strength.
1
3Ph
L
L
L
N
L
N
2
NOTE
It is strongly recommended to verify the presence of a surge protection device (SPD) on main power line and of circuit breakers
connected to the external and internal unit's control box
* See table of electrical connections
WARNING
After carrying out the connections between the indoor and outdoor unit, put back both panels of the respective units.
1Ph
L N
3
L
N
2
5
3
4
B T
T
ON
OFF
XXA*
2A
2A
30mA
N
N
N
N
2
3G 0.75mm
HV
OUT
BUF
IN 3
AUX 2
1. Power supply
connection
terminal block
2. Power supply cable
3. Ground connection
4. BUS onnection
5. Electrical panel
HV
HV
OUT
PM AUX
V 1
V 2
ST 1
IN 1
IN 2
AUX 1
N
L
N L
L
/ 69