Promise Technology Vess A Series Product Manual page 207

Hide thumbs Also See for Vess A Series:
Table of Contents

Advertisement

Vess A6120 Product Manual
rc
Usage
rc [-a <action>] [-l <LdId>]
rc -a start -l <LdId> [-n] [-p]
rc -a stop -l <LdId>
rc -a pause -l <LdId>
rc -a resume -l <LdId>
Summary
The rc command starts, stops, pauses and resumes a Redundancy Check and monitors the
progress of a running Redundancy Check.
Options
-a <action>
Specifies action to perform.
list
(Default) Displays active and paused Redundancy Checks and their status.
start
stop
pause
resume
-l <Ld ID>
Specifies the logical drive ID on which to run the Redundancy Check.
-n Do not fix inconsistent data. This option causes Redundancy Check to run without correcting
inconsistent data. All inconsistency errors are reported.
-p Pause on error. This option causes Redundancy Check to pause when it encounters
inconsistent data. The default is to continue on error.
Starts a Redundancy Check.
Stops a Redundancy Check.
Pauses a Redundancy Check.
Resumes a paused Redundancy Check.