Chapter 10 Digital Channel
ADO, ADDR, BIT, CAS, CLK, CS, DATA, HALT, INT, LOAD, NMI, OUT, PAS, PIN,
RDY, RST, RX, TX, WR, MISO, MOSI, and D0-D15.
Input a label manually
Press Label to open the label input interface. You can input the label manually.
For details, refer to descriptions in "Channel Label".

Group Setting

Press On/Off → Group to enter the user-defined group setting menu. You can
randomly grouping or ungrouping any channels of the 16 digital channels. You can
also directly press More to enter the menu to group or ungroup channels according
to your needs.
Group:
For grouping, the operations for the 4 user-defined groups (Group1, Group2,
Group3, and Group4) are the same. Here take Group1 as an example.
Press Group1 to open the D0-D15 channel selection list (the status icon is
located at the left side of each channel). Rotate the multifunction knob
press Group1 continuously to select the channel(s) to be added to Group1.
Then, press down the multifunction knob to add the selected channel(s) to
Group1. The channel(s) that has/have been added to Group1 is/are marked with
the status icon
is/are marked with the status icon
Use the same method to group the other channels. Each channel can only be
added to one single group, and the channels that have been added to other
group cannot be selected. You can perform group operation on 16 digital
channels (D0-D15).
Ungroup:
Press UnGroup to open the group list. Rotate the multifunction knob
press UnGroup continuously to select any channel group, then press down the
knob to ungroup the channels.
Note:
You can only ungroup the digital channel group.
If no group is set, the Ungroup menu and the Group On/Off menu are
grayed out and disabled.