7. Installation

The B024-H4U08 and B024-H4U16 can be stacked on a desktop or rack mounted at the front or rear of a rack.
Notes:
• Allow at least 2 inches (5.1 cm) on each side for adequate ventilation and 5 inches (12.7 cm) at the rear for power cord and
cable clearance.
• The standard rack mounting kit does not include screws or cage nuts. If you need additional screws or cage nuts, contact your
rack dealer.

7.1 Stacking

The B024-H4U08 and B024-H4U16 can be placed on any level surface that can safely support the weight of the device
and the weight of the attached cables. Make sure the surface is clean and free of any materials that can block the
exhaust vents or otherwise interfere with normal operation of the switch.
To place the B024-H4U08 and B024-H4U16 (or to stack units if you are cascading them), remove the backing material
from the bottom of the rubber feet and stick them onto the bottom panel at the corners, as shown below:

7.2 Rack Mounting

7.2.1 Front Rack-Mounting

1
Remove each of the screws from the left and right sides near the front of the unit.
12