12. RS-232 Operation

12.4.5 Set Baud Rate

The Set Baud Rate command allows you to configure the baud rate setting for the serial port connection. The default
baud rate is 19200.
Use the Formula → to set Parameters → to create a Command.
Formula
Command + Control + [Enter]
Parameters
Command
baud
Control
19200
38400
9600
Enter
Enter
Set Baud Rate Commands
The available formulas for the Set Baud Rate commands are as follows:
1
Command + Control + [Enter]
For example, to set the baud rate to 19200, type the following:
baud 19200 [Enter]
2
Command + Control + [Enter]
For example, to set the baud rate to 38400, type the following:
baud 38400 [Enter]

12.4.6 Switch Port

The Switch Port command allows you to switch ports. The default port is 01.
Use the Formula → to set Parameters → to create a Command.
Formula
Command + Control + [Enter]
Parameters
Command
sw
Control
ixx
Enter
Enter
Description
Baud rate command
Description
Set baud rate to 19200 (Default)
Set baud rate to 38400
Set baud rate to 9600
Description
Enter and send out command
Description
Switch Port command
Description
Input port number
xx= 01~08 (B024-H4U08); 01~16 (B024-H4U16)
Description
Enter and send out command