Sony XKS-C9111 User Manual page 484

Multi format switcher system with integrated control panel
Hide thumbs Also See for XKS-C9111:
Table of Contents

Advertisement

2
Select the port connected to the target AMP
compatible device to set.
3
Press [Port Setting].
The AMP Setting menu (7355.8) appears.
The slot number/port number, device type, port name,
and control panel number appear at the top of the status
area. The setting status of each item appears at the
bottom of the status area.
4
In the <TC Sense> group, select the type of timecode
sense.
Zero based: Mode in which timecode is sensed
(detected), taking the first frame of the loaded file
as 00:00:00:00.
SOM based: Mode in which sensing occurs using the
timecode saved in the loaded file.
Note
The details of the above operation modes depend on
the connected device. For more information, refer to
the documentation for the connected device.
5
Select the target item to set.
1. Maximum Open Delay: Maximum time required
to open a file
2. Maximum Cueup Delay: Maximum time required
to cue up a file
3. Play After Cueup Delay: Delay time from the
cued-up state to begin playback
4. Stop Delay: Delay time from issuing the Stop
command until actually stopping
5. Still Delay: Delay time from issuing the Still
command until actually stopping
6. Command Delay (Auto Mode): Delay time from
issuing the Auto Mode On/Off command until the
command takes effect
7. Command Delay (Out Preset): Delay time from
issuing the Out Preset command until the
command takes effect
8. Command Delay (Preview In Preset): Delay time
from issuing the Preview In Preset command until
the command takes effect
9. IP Address: IP address setting
10. TCP/IP Port: TCP/IP port number setting
11. Video Port: Video port number (1 to 4) setting
12. Internal Parameter (1): Reserved for future use
(set to 255)
13. Internal Parameter (2): Reserved for future use
(set to 255)
14. Internal Parameter (3): Reserved for future use
(set to 255)
6
Set the response speed or value.
No.
Parameter
2
Setting
When "IP Address" is selected
Press [IP Address]. Enter the address using the
keyboard window, press [Enter], then skip to step 8.
When "TCP/IP Port" is selected
Press [TCP/IP Port]. Enter the port number using the
numeric keypad window, press [Enter], then skip to
step 8.
7
Press [Set].
8
Repeat steps 5 to 7 as required to make the settings for
other items.
Configuring detailed settings for a TCP/IP
connected device
1
In the <DCU Select> group of the Engineering Setup
>DCU >Serial/Net Port Assign menu (7355), select
the target to set (DCU1 or DCU2).
2
Select the port connected to the target device to set.
3
Press [Port Setting].
The General tcp/ip Setting menu (7355.9) appears.
The slot number/port number, device type, port name,
and control panel number appear at the top of the status
area. The setting status of each item appears at the
bottom of the status area.
4
Select the target item to set.
1. IP Address: IP address setting
2. Port: Port number setting
3. Internal Parameter (1): Reserved for future use
(set to 255)
4. Internal Parameter (2): Reserved for future use
(set to 255)
5. Internal Parameter (3): Reserved for future use
(set to 255)
6. Internal Parameter (4): Reserved for future use
(set to 255)
7. Internal Parameter (5): Reserved for future use
(set to 255)
8. Internal Parameter (6): Reserved for future use
(set to 255)
9. Internal Parameter (7): Reserved for future use
(set to 255)
10. Internal Parameter (8): Reserved for future use
(set to 255)
11. Internal Parameter (9): Reserved for future use
(set to 255)
484
Adjustment
Response speed or value

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents