selected page number and name, and the lower right
side shows a list of assignable functions.
2
In the <Bank Select> group, select the target bank to
set.
3
Select the target page to set.
No.
Parameter Adjustment
1
Page
Page selection
4
Press the target button to make an assignment.
5
In the list on the right, select the function to assign.
Set the numerical value of the "?" part of the function
name using the following parameters.
No.
Parameter Adjustment
3
Row
Button row selection
a)
4
Key
Key selection
Aux
AUX bus selection
DME
DME channel selection
Util/Sbox
Utility/shotbox bank selection
Macro
Macro register selection
Mode
Display mode selection
Level
Level selection button selection
Button
Table
Cross-point assign table selection
a) The parameters will vary depending on the selected function name.
6
Press [Set].
To release the assignment
Select the target button to release, then press [Clear].
To return button assignments to the defaults
Press [Default Recall], check the message, then press
[Yes].
The button assignments on all pages (1 to 14), including
the Jump Page Assign menu (7326.17) settings, are
returned to the defaults.
To rename a page
1
Select the target page number to set, and press [Page
Name].
2
Enter a name of up to 12 characters in the keyboard
window, and press [Enter].
Note
Lower case characters may be entered, but the entered
characters are displayed as upper case characters on
the buttons in the cross-point pad.
About re-entry button assignment
The following re-entry buttons can be assigned to buttons
on the cross-point pad.
• ROW-n P/P OUT1, ROW-n M/E-1 OUT1 to ROW-n
M/E-5 OUT1 (n = 1 to 4)
• ROW-n P/P OUT6, ROW-n M/E-1 OUT6 to ROW-n
M/E-5 OUT6 (n = 1 to 4)
The button numbers and video/key pair numbers of re-
entry buttons is fixed to the following.
Button name
Button
(n = 1 to 4)
number
ROW-n P/P
284
OUT1
ROW-n
281
M/E-1 OUT1
ROW-n
282
M/E-2 OUT1
ROW-n
283
M/E-3 OUT1
ROW-n
285
M/E-4 OUT1
ROW-n
286
M/E-5 OUT1
ROW-n P/P
294
OUT6
ROW-n
291
M/E-1 OUT6
ROW-n
292
M/E-2 OUT6
ROW-n
293
M/E-3 OUT6
ROW-n
295
M/E-4 OUT6
ROW-n
296
M/E-5 OUT6
The re-entry video/key numbers are set as the pair numbers
by default. Use the defaults as-is, since changing the
settings will make it impossible to select the correct
signals.
Setting the HOME page of the cross-point
pad
This sets the page that is displayed when the [HOME]
button on the cross-point pad is pressed.
1
In the <Bank Select> group of the Engineering Setup
>Panel >Operation >Xpt Module Operation menu
(7326.12), select the target bank to set.
2
In the <Xpt Pad> group, press [Home Page Set].
435
V/K pair
V default
K default
number
setting
setting
211
P/P OUT1
P/P OUT1
221
M/E-1
M/E-1
OUT1
OUT1
231
M/E-2
M/E-2
OUT1
OUT1
241
M/E-3
M/E-3
OUT1
OUT1
251
M/E-4
M/E-4
OUT1
OUT1
261
M/E-5
M/E-5
OUT1
OUT1
216
P/P OUT6
P/P OUT6
226
M/E-1
M/E-1
OUT6
OUT6
236
M/E-2
M/E-2
OUT6
OUT6
246
M/E-3
M/E-3
OUT6
OUT6
256
M/E-4
M/E-4
OUT6
OUT6
266
M/E-5
M/E-5
OUT6
OUT6

Hide quick links: