TDK-Lambda GH10-100 User Manual page 124

Table of Contents

Advertisement

[SOURce]:CURRent:SLEW:UP <NRf+>
Function
Sets a digital current reference up programming slew rate.
Parameters
0.0001 ~ 999.99
Unit
A/mS
Query
[SOURce]:CURRent:SLEW:UP?
Return
<NR2>
Example
:CURR:SLEW:UP 1 Sets a digital current reference up programming slew to
1A/mSec.
:CURR:SLEW:UP? returns a digital current up programming slope value.
:CURR:SLEW:UP? MAX and :CURR:SLEW:UP? MIN return the maximum and
minimum digital current reference up programming slope value.
[SOURce]:CURRent:MODE <DSC>
Function
Sets the current sequence mode.
Parameters
0|1|2, NONE|LIST|WAVE
Query
[SOURce]:CURRent:MODE?
Return
<DSC> NONE|LIST|WAVE
[SOURce]:VOLTage:EXTernal:MODE <DSC>
Function
Sets the voltage programming source: Front panel/Communication (Digital),
external voltage, or external resistor.
Parameter
0|1|2 or DIG|VOL|RES
Query
[SOURce]:VOLTage:EXTernal:MODE?
Return
<DSC> DIG|VOL|RES
[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Function
Sets a digital programming output voltage value.
Parameters
The range is limited by the power supply model, OVP, and UVP settings.
Unit
V
Query
[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]?;
Return
<NR2> 5-digits format
Example
:VOLT? returns the present programmed voltage level.
:VOLT? MAX and :VOLT? MIN return the maximum and minimum
programmable voltage level.
113

Advertisement

Table of Contents
loading

Table of Contents