TDK-Lambda GH10-100 User Manual page 122

Table of Contents

Advertisement

[PROGram]:WAVE:TIME <NRf+>,{<NRf+>}
Function:
Specifies the time interval of each slope between 2 points of a WAVE.
The function defines up to 100 parameters.
Parameters
0.001 to 129,600 seconds. Default: 0.001s
Unit
S
Query
[PROGram]:WAVE:TIME?
Return
<NR2>,{<NR2>}
Example
WAVE:TIME .6,1.5,1.5,.4
A delay of ~100mSec is required after the [PROGram]:WAVE:TIME command if long sequences
are used, prior sending any additional command.
[PROGram]:WAVE:VOLTage <NRf+>,{<NRf+>}
Function
Specifies output voltage points in a wave.
Voltage points are separated by commas.
The function accepts up to 100 parameters.
Parameters
The range is limited by the power supply voltage programming range
(including UVP & OVP settings).
Unit
V
Query
[PROGram]:WAVE:VOLTage?
Return
<NR2>,{<NR2>} 5-digits format
Example
WAVE:VOLT 2.0,2.5,3.0; WAVE:VOLT MAX,2.5,MIN
A delay of ~100mSec is required after the [PROGram]:WAVE:VOLTage command if long
sequences are used, prior sending any additional command.
[PROGram]:LIST:CURRent, [PROGram]:LIST:VOLTage, [PROGram]:WAVE:CURRent and
[PROGram]:WAVE:VOLTage commands share the same memory space.
For example, if [PROGram]:LIST:CURRent command is sent, [PROGram]:LIST:VOLTage,
[PROGram]:WAVE:CURRent and [PROGram]:WAVE:VOLTage are set to zero.
[PROGram]:LIST:DWELl and [PROGram]:WAVE:TIME commands share the same memory
space.
For example, if [PROGram]:LIST:DWELl command is sent, [PROGram]:WAVE:TIME is set to zero.
NOTE
NOTE
NOTE
NOTE