FEVE?
Query
Returns the value of the Questionable Group Event register, which is a read-only
register.
Fault Events are updated as a transition from 0 to 1. Reading the register clears it
(All Zeros).
Returns
<NRh>
STAT?
Query
Returns the value of the Operation Group Condition register, which is a read-
only register that holds the real-time status of the power supply.
Returns
<NRh>
Example
09FA
SENA <NRh>
Function
Sets the value of the Operation Group Enable register. This register is a mask to
enable specific bits from the Condition register to the Event register.
Parameters
0...FFFF
Query
SENA?
Returns
<NRh> 0...FFFF
SEVE?
Query
Returns the value of the Operation Group Event register, which is a read-only
register.
Fault Events are updated as a transition from 0 to 1. Reading the register clears it
(All Zeros).
Returns
<NRh>