Maintenance Frequency - Seco EASYSHRINK EVO User Instructions

Table of Contents

Advertisement

MAINTENANCE FREQUENCY

1. DAILY MAINTENANCE
- Clean the device.
- Control the correct running and good condition of the device.
1
Check the condition of the inductors.
2
Check the condition of the heat-focusing plates.
3
Check the condition of the stop rods.
2. MONTHLY MAINTENANCE
4
Check the water level of the water-cooling unit.
5
Check the water temperature.
In the case of significant condensation, it is advisable to slightly increase the water
temperature to prevent condensation on the bells and the tool holder.
3. TWICE A YEAR
The water-cooling unit must be drained off.
Turn off the general power supply by pressing the switch at the back of the device.
Open the lid on the top of the water-cooling unit (4 screws to be removed).
Simultaneously pull the 2 white pull studs in opposite directions in order to open
the tank then empty the tank.
Wastewater is considered to be polluted and must be treated according to environ-
mental constraints.
Fill the tank up with pure tap water until the indicated level is reached
(7.5 < pH < 9 / 7°C (44.6°F) < TH < 15°C (59°F)).
Close the tank again, replace the lid and screw it back.
Switch on the general switch at the back of the device.
1
2
3
4
5