Rmon Alarm - ZyXEL Communications RGS Series User Manual

Table of Contents

Advertisement

5.3.27 RMON Alarm

Configure RMON Alarm table on this page. The entry index key is ID.
Object
Delete
ID
Interval
Variable
Sample Type
Value
Startup Alarm
Rising Threshold
Rising Index
Falling Threshold
Falling Index
Check to delete the entry. It will be deleted during the next save.
Indicates the index of the entry. The range is from 1 to 65
Indicates the interval in seconds for sampling and comparing the rising and falling
threshold. The range is from 1 to 2^31-1.
Indicates the particular variable to be sampled, the possible variables are:
InOctets: The total number of octets received on the interface, including framing
characters.
InUcastPkts: The number of uni-cast packets delivered to a higher-layer protocol.
InNUcastPkts: The number of broad-cast and multi-cast packets delivered to a
higher-layer protocol.
InDiscards: The number of inbound packets that are discarded even the packets
are normal.
InErrors: The number of inbound packets that contained errors preventing them
from being deliverable to a higher-layer protocol.
InUnknownProtos: the number of the inbound packets that were discarded
because of the unknown or un-support protocol.
OutOctets: The number of octets transmitted out of the interface , including framing
characters.
OutUcastPkts: The number of uni-cast packets that request to transmit.
OutNUcastPkts: The number of broad-cast and multi-cast packets that request to
transmit.
OutDiscards: The number of outbound packets that are discarded event the
packets are normal.
OutErrors: The number of outbound packets that could not be transmitted because
of errors.
OutQLen: The length of the output packet queue (in packets).
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute: Get the sample directly.
Delta: Calculate the difference between samples (default).
The value of the statistic during the last sampling period.
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
RisingTrigger alarm when the first value is larger than the rising threshold.
FallingTrigger alarm when the first value is less than the falling threshold.
RisingOrFallingTrigger alarm when the first value is larger than the rising
threshold or less than the falling threshold (default).
Rising threshold value (-2147483648-2147483647).
Rising event index (1-65535).
Falling threshold value (-2147483648-2147483647)
Falling event index (1-65535).
Description
73