1D Symbologies
Enter/Exit Programming Mode
MSI Length Control
This feature specifies either variable length decoding or fixed length decoding for the MSI sym-
bology.
For variable length decoding, a minimum and maximum length may be set.
Variable Length:
For fixed length decoding, two different lengths may be set.
Fixed Length:
$CMSLC00(CR)
DEFAULT
MSI Length Control = Variable Length
$CMSLC01(CR)
MSI = Fixed Length