Enter/Exit Programming Mode

Global Prefix/Suffix

This option sets up to 20 characters each from the set of ASCII characters or any hex value from
00 to FF. The characters may be added as a prefix (in a position before the bar code data, also
called a header) and/or as a suffix (in a position following the bar code data, also called a
footer). See
page 245
To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE bar code above to place
the unit in Programming Mode, then the "Set Global Prefix" or "Set Global Suffix," bar code fol-
lowed by the digits (in hex) from the Alphanumeric characters in
senting your desired character(s). If less than the expected string of 20 characters are selected,
scan the ENTER/EXIT bar code to terminate the string. Exit programming mode by scanning the
ENTER/EXIT bar code again.
$CLFSU
Set Global Suffix
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
54
for more detailed instructions on setting this feature.
DEFAULT
$CLFPR
~
No Global Prefix
Global Suffix = 0x0D (CR)
QuickScan™ I QD24XX/QBT24XX/QM24XX
Appendix D, Keypad
Set Global Prefix
CANCEL
repre-