Chimney Sweep Instructions - DeDietrich DTGE130-35 Eco.NOxPlus Technical Instructions

Gas fired condensing boiler
Table of Contents

Advertisement

16. Chimney sweep instructions

16 Chimney sweep instructions
Setting the boiler output for measuring emissions
Tilt the flap on the control panel.
Press key
and
Use keys + and - to switch from
-
: Maximum boiler output
-
: Minimum output
In the display area:
Fan speed (rpm)
Ionization current (µA)
Fan speed (rpm) (Natural gas)
Fan speed (rpm) (Propane)
Ionization current (µA)
76
simultaneously for 2 seconds.
to
DTGE130-35,
1100
4
4600
4200
9
DTG(E)130 - 35/45/65/90/115 Eco.NOxPlus
EMISSION MES. 88.8°: Boiler temperature
EMISSION MES. 8888: Fan speed
EMISSION MES. 88.8uA: Ionization current
DTG130-45
DTG130-35
1100
4
5200
4600
9
DTG130-65
DTG130-90
1200
1200
4
4
5200
6200
4600
6100
9
9
15/02/2011 - 300014279-001-J
DTG130-115
1300
4
7000
6700
9