DeDietrich ELIDENS User Manual

DeDietrich ELIDENS User Manual

Gas fired condensing boiler

Advertisement

EN
ELIDENS
Gas fired condensing boiler
DTG 1300 Eco.NOx Plus / V130
DTG(E) 130 Eco.NOx Plus
User Guide
300002784-001-F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELIDENS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DeDietrich ELIDENS

  • Page 1 ELIDENS Gas fired condensing boiler DTG 1300 Eco.NOx Plus / V130 DTG(E) 130 Eco.NOx Plus User Guide 300002784-001-F...
  • Page 2: Table Of Contents

    Contents Used symbols ................3 Important recommendations .
  • Page 3: Used Symbols

    1. Used symbols 1 Used symbols Caution danger Reference Risk of injury and damage to equipment. Attention must be Refer to another manual or other pages in this instruction paid to the warnings on safety of persons and equipment manual Specific information DHW: Domestic hot water Information must be kept in mind to maintain comfort...
  • Page 4: Aeration

    2. Important recommendations 2.1 Aeration 2.1.1 Chimney versions Do not obstruct the air inlets in the room (even partially). Germany: the cross section of the ventiliation vents, which are compulsory in the room in which the boiler is installed, must comply France: the cross section of the aeration vent, which is compulsory with the VDI 2050 form 1 standard and with other prevailing in the boiler room in which the boiler is installed, must comply with the...
  • Page 5: Description

    3. Description 3 Description 3.1 Boilers The models presented are marketed in the various countries according to the countries' specific sales programme. Package HE1 - HE2 Condensing boiler module Electronic manometer Automatic air vent Expansion vessel (12 litres) Siphon Modulating pump Safety valve (3 bar) Inverter valve Stop cock...
  • Page 6 3. Description Package HE3 - HE4 - HE13 - HE14 Condensing boiler module Electronic manometer Automatic air vent Expansion vessel (12 litres) Siphon Modulating pump Safety valve (3 bar) Inverter valve Stop cock 10 Domestic hot water safety valve 7 bar 11 Non-return valve 12 Disconnector 13 Funnel...
  • Page 7 3. Description Package GN1 - GN2 Condensing boiler module (15 kW - 25 kW) Electronic manometer Siphon Heating return Condensates discharge Heating outlet Package GN3 - GN4 Condensing boiler module (15 kW - 25 kW) Electronic manometer Automatic air vent Expansion vessel (12 litres) Siphon Modulating pump...
  • Page 8: Control Panel

    3. Description 3.2 Control panel Electromechanical components Main ON/OFF switch On light / Alarm Red LED lit: Burner in safety condition Flashing red Led: abnormal operation Safety control box reset button Timed circuit breaker (4 A) A second electrical safety device can be found on the card which is accessible when the hoods are removed. This is a fuse: F1 4 amperes, delayed action DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F...
  • Page 9 3. Description Display Text and numerical display Graphic display bar for the programme in circuit A, B or C Light area: Reduced temperature heating period or tank load disabled Dark area: Comfort temperature heating period or tank load enabled Flashing cursor showing the current time Number display (current time, adjusted values, parameters, etc.) Active programme display, P1, P2, P3, P4 E: Summer mode activated...
  • Page 10 3. Description Keys accessible when the flap is closed Setting the temperatures Comfort temperature Reduced temperature Domestic hot water temperature Is used to adjust the selected temperature Operating mode selection keys AUTO Heating according to the time programme Forced Comfort mode: - until midnight if flashes - all the time if...
  • Page 11 3. Description Keys accessible when the flap is open Manual "Summer" shutdown key The heating is switched off and DHW production is ensured. The symbols and Su are displayed. "Standard" programme key Reset of all time programmes Fitter settings access key Key for access to setting and measurements Page scrolling Line scrolling...
  • Page 12: Energy-Saving Boiler

    4. Energy-saving boiler 4 Energy-saving boiler This boiler handles all the functionalities that one may expect of a condensing boiler. Cutting edge technologies have been used not only in its exceptionally economic design in terms of finance and energy, and therefore also of environmental protection, but have also been applied to provide maximum comfort: heating for the whole house, hot water, incredibly simple to use and trouble-free operation thanks to its reduced noise level.
  • Page 13: Start-Up

    5. Start-up 5 Start-up Initial commissioning must be done by a qualified 3. Control panel: professional. Set the On/Off switch to 1. Check the water pressure in the installation several times a year. Create a requirement for heat. Top up with more water if necessary. 2.
  • Page 14: Alarm Messages

    8. Alarm messages 8 Alarm messages Faults In the event of a fault, the display may show the following messages. Contact your fitter. Message Probable causes Solution Igniter fault Ionization error BURNER FAILURE Gas valve defective No gas or presence of air in the pipe Incorrect positioning of the electrode Ignition cable or electrode connector CVI8 FAILURE...
  • Page 15: Warranty Terms

    8. Alarm messages Warranty You have just purchased one of our appliances and we thank you Italy for the trust you have placed in our products. Please note that your The duration of our warranty is shown on the certificate delivered appliance will provide good service for a longer period of time if it is with the appliance.
  • Page 16 All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations. 10/11/2009 DE DIETRICH THERMIQUE 57, rue de la Gare F- 67580 MERTZWILLER - BP 30...

Table of Contents