Installing An Optional Wall Switch (Not Supplied By Regency) Or Thermostat (Part # 910-407 Or 910-404/P) - Regency Grandview G800C-1 Manual

Table of Contents

Advertisement

Installing an Optional Wall Switch (Not Supplied by Regency) or Thermostat (Part # 910-407 or
910-404/P)
A wall-mounted On/Off switch or Thermostat may be used to operate the
on/off functionality of the main burner. External electricity is only required
to operate the convection fan, and is not required to operate the fireplace.
The millivolt gas control system uses the pilot flame to generate enough
electricity to operate the main burner. To install a wall switch or thermostat,
follow the directions below:
1. Remove safety screen, glass door and bottom cover panel (see
manual for details).
2. Locate the black wire running from the valve to the unit on/off switch.
Unclip the wire holder clip and remove the black wire from the clip.
f i r e - p a r t s . c o m
3. Break the connection between the inline wire connectors on the black
wire. The wall switch or thermostat wiring will run to these two connec-
tors.
4. Route the wiring for your wall switch or thermostat from the wire
connectors through the hole on the right side of the unit, using the
supplied black plastic strain relief to secure the wiring as it passes
through the unit.
5. Install the wall mounted on/off switch or thermostat as per local elec-
trical code requirements.
Refer to the manual for the full wiring diagram.
installation