maintenance

Valve Replacement

Removing Valve
1. Shut off the gas and electrical supply.
2. Remove the safety screen.
3. Remove the glass door.
4. Remove the logs and glass.
5. Remove the log grate assembly by removing 2
screws and sliding tray forward to remove.
f i r e - p a r t s . c o m
Diagram 1: Remove left and right screws.
6. Remove lower (brick or enamel) panel.
7. Slide the burner assembly to the right to release
it from the orifice, then lift it out.
Diagram 2
8. Remove 2 screws securing the fan access
(Diagram 3).
Diagram 3
9. Disconnect the inlet gas line.
88 | Grandview
G800C-1 Gas Fireplace
®
10. Disconnect the two switch wires from the valve,
as shown below.
Diagram 4
Switch wires
11. Disconnect spark electrode from DC sparker
box, as shown below.
Electrode wire
Diagram 5
12. Remove the 8 screws securing the valve tray
assembly in place (Diagram 6) and then lift out
entire assembly.
Diagram 6
13. Remove Philips head screws securing DC
sparker box, as shown below.
Philips head screw
Diagram 7
Replacing Thermocouple
1. Follow steps 1-13 for replacing valve.
2. Disconnect thermocouple at gas valve.
Thermocouple
3. Disconnect thermocouple at pilot assembly end.
4. Replace thermocouple.
5. Reverse steps 1-13.