installation

Chase Vent Installation - Cool Wall

Framed Opening must be at least 2-3/8" (60mm) tall, and at least 33-3/8" (848mm) wide to accomodate the Chase vent. The top of the Chase
vent opening must be 2" (51 mm) or less from the top of the chase enclosure. Fasten the Chase vent with screws and construction adhesive.
If the optional Regency chase vent is not being used, a minimum 66in
ing temperatures. This can be achieved in a number of ways including a reveal at the top of the chase.
f i r e - p a r t s . c o m
Max. 2"
26 | Grandview
G800C-1 Gas Fireplace
®
920-150
Side View
Ceiling
Top of chase enclosure
2
(426cm
2
) opening in the enclosure is required to maintain safe operat-
Max. 2"
1
G800EC
Ceiling
09.04.19