Vertical Flue Extension Kit (Part #946-756); Ceiling Firestop / Firestop Spacer (Part #946-757) - Regency Grandview G800C-1 Manual

Table of Contents

Advertisement

installation

Vertical Flue Extension Kit (Part #946-756)

VERTICAL FLUE EXTENSION KIT (PART # 946-756)
20 foot (6.1 m) Flex pipe Extension
(Used in conjunction with the 946-755 Vertical Flex kit and 948-367/P flex
to flex adaptor).
CEILING FIRESTOP/FIRESTOP SPACER
1. Stretch out both inner 4" (102 mm) and outer 6 7/8" (175 mm) pipe up to
( PART # 946-757)
a maximum of 20 feet.
Used in conjunction with the 946-755 Vertical Flex Kit and 946-756 Vertical
Note :The inner and outer pipes may be cut if only a short length is required.
Flex Extension Kit/Horizontal Power Vent Kit.
2. Install spring spacers around 4" (102 mm) inner pipe as shown.
A ceiling firestop/firestop spacer must be installed when passing through
Slide outer flex pipe over and all the way down the 4" pipe.
each floor or ceiling level. To install the ceiling firestop/firestop spacer in
a flat ceiling or floor joist, cut a 10- ¼ inch square hole, frame it as show
3. Apply a bead of Mill Pac around the perimeter of the 4" (102 mm)
in Diagram 1, and install the ceiling firestop. Slide the top attic insulation
inner collar of the flex adapter and slip the 4" (102 mm) inner flex pipe
spacer onto the top of the attic insulation shield/firestop (see Diagram 1a).
from the Vertical termination kit over the flex adapter ensuring that the
Secure with 4 screws/nails. If more than one firestop is required, these can
inner flex pipe overlaps the collar by at least 1-3/8" (35 mm). Fasten with
be purchased separately.
3 screws.
• The ceiling firestop/firestop spacer may be cut down to size if the
4. Apply a bead of Mill Pac around the perimeter of the 6-7/8" (175 mm)
shield is too high for the application.
outer collar of the flue adapter and slip it over the 6-7/8" (175 mm) outer
flex pipe from the vertical termination kit ensuring that the outer flex pipe
overlaps the collar by at least 1-3/8" (35 mm). Fasten with the 3 screws.
5. Repeat steps to secure the other end of the flex adapter using the flex kit.
f i r e - p a r t s . c o m
6. See Vertical Vent installation instructions for installation of the complete
vent system.
Note: If an offset is necessary in the attic or floor joists it is important to
sup-port the vent pipe every 3 feet (0.91 m) to avoid excessive stress and
sagging of the vent pipe. Wall straps are provided (3 in total) for this
purpose.
919-698
All round/plumbers strapping may also be used if further supports are
required.
CEILING FIRESTOP/FIRESTOP SPACER

Ceiling Firestop / Firestop Spacer (Part #946-757)

( PART # 946-757)
Used in conjunction with the 946-755 Vertical Flex Kit and the 946-756 Verti-
cal Flex Extension Kit/Horizontal Power Vent Kit.
A ceiling firestop/firestop spacer must be installed when passing through
each floor or ceiling level. To install the ceiling firestop/firestop spacer in
a flat ceiling or floor joist, cut a 10- ¼ inch square hole, frame it as show
in Diagram 1, and install the ceiling firestop. Slide the top attic insulation
spacer onto the top of the attic insulation shield/firestop (see Diagram 1a).
Secure with 4 screws/nails. If more than one firestop is required, these can
be purchased separately.
• The ceiling firestop/firestop spacer may be cut down to size if the
shield is too high for the application.
62 | Grandview
G800C-1 Gas Fireplace
®
919-696
919-698
4" (102 mm) inner
pipe 20ft. (6.1 m)
-1/4
60
Ceiling firestop
Diagram 1
6-7/8" (175 mm)
outer flex pipe
Diagram 1a
20 ft (6.1 m)
1
-1/4
60
Ceiling firestop
Diagram 1
Diagram 1a
1
1
10 spring spacers
Termination Cap
Storm Collar
Flashing
flex adaptor
Firestop spacer to prevent
debris from falling into the ceiling
firestop
Roof support
3 wall straps
Ceiling firestop
Enclosure
Ceiling firestop
06.12.18
Termination Cap
Storm Collar
Flashing
Firestop spacer to prevent
debris from falling into the ceiling
Roof support
firestop
Ceiling firestop
Enclosure
Ceiling firestop
06.12.18
08.10.16