Pass/Fail - Rigol DS1302CA User Manual

Digital oscilloscopes
Hide thumbs Also See for DS1302CA:
Table of Contents

Advertisement

RIGOL

Pass/Fail

The Pass/Fail function monitors changes of signals and output pass or fail signals by
comparing the input signal is within the pre-defined mask. The testing results not
only can be displayed on screen or output by isolated pass/fail port but also can be
alarmed if turn on system sound.
Press Utility→Pass/Fail to go to the following menu.
Figure 2-84
Table 2-51 The Pass/Fail menu (Page 1/2)
Figure 2-85
Table 2-52 The Pass/Fail menu (Page 2/2)
2-62
Menu
Setting
ON
Enable Test
OFF
CH1
Source
CH2
(RUN)
Operate
(STOP)
ON
Msg display
OFF
Menu
Settings
Fail
Fail +
Output
Pass
Pass +
Stop
ON
on Output
OFF
Mask Setting
Comments
Turn on Pass/Fail test.
Turn off Pass/Fail test.
Select Pass/Fail test on CH1.
Select Pass/Fail test on CH2.
Pass/Fail test stopped, press to run.
Pass/Fail test running, press to stop.
Turn on Pass/Fail information display.
Turn off Pass/Fail information display.
Comments
Output when Fail condition detected.
Output and beep when Fail condition
detected.
Output when Pass condition detected.
Output and beep when Pass condition
detected.
Stop test when output occur.
Continue test when output occur.
Go to mask setting menu.
User‟s Guide for DS1000CA Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds1000ca seriesDs1202caDs1102caDs1062ca

Table of Contents