1.888.610.7664
13. Memory function (KEW3552/ 3552BT only)
This instrument can save voltage, insulation resistance, and low-resistance
measurement results in the internal memory, 1000 results max. Data can be
saved with two different site number for easy recognition. (Not available on
KEW3551.)
● Data to be saved:
M easured voltage, insulation resistance, and low-resistance, DAR/ PI,
1-min value, time and date, measurement function, and the data and site
no. selected when saving the result.
● Data can be recalled:
M easured voltage, insulation resistance, and low-resistance values,
measurement function, and the data no. and site no. selected at saving the
result. To check DAR/ PI value, 1-min value, time and date information, you
need to transfer the data to PC. Please refer to 14. Infrared data
transmission for further detail.
Items saved with the
measured result
Select and assign a number for the
Data no.
data to be saved. The number will be
automatically increased by 1.
SITE No.1
Select and assign any number for the
(Site No. 1)
measurement data. (depending on the
SITE No.2
buildings or circuits)
(Site No. 2)
13-1 Saving method
(1) M easured result is displayed and being held when a measurement
completes. (As for voltage measurement, data can be saved during a
measurement.)
Indicating the data
hold status.
(2) Press the MEMORY button (< 1 sec.).
̶ 37 ̶
www.calcert.com
15
10
20
5
25
0
30
Selectable
Details
range
0 - 999
0 - 99
0 - 99
Fig. 13-1
sales@calcert.com