Item
ALC Area Selector
ALC Area Enable
ALC Area Enable All
ASC Min.
ASC Max.
AGC Min.
AGC Max.
AGC/ASC Control Speed
n) JAI Custom Control AWB
AWB Area Selector
AWB Area Enable
AWB Area Enable All
AWB Control Speed
AWB Status
Setting range
Low Right,
Low Mid-Right,
Low Mid-Left,
Low Left,
Mid-Low Right,
Mid-Low Mid-Right,
Mid-Low Mid-Left,
Mid-Low Left,
Mid-High Right,
Mid-High Mid-Right,
Mid-High Mid-Left,
Mid-High Left,
High Right,
High Mid-Right,
High Mid-Left,
High Left
True, False
True, False
100 to 13426
101 to 13427
100 to 1599
101 to 1600
1 (slow) to 8 (fast)
Low Right,
Low Mid-Right,
Low Mid-Left,
Low Left,
Mid-Low Right,
Mid-Low Mid-Right,
Mid-Low Mid-Left,
Mid-Low Left,
Mid-High Right,
Mid-High Mid-Right,
Mid-High Mid-Left,
Mid-High Left,
High Right,
High Mid-Right,
High Mid-Left,
High Left
True, False
True, False
1 (slow) to 8 (fast)
— 54 —
GO-5100M-USB / GO-5100C-USB
Default value
Low Right
Select an ALC metering area.
False
Enable/disable the metering area where
selected metering area.
True
On: Operate ALC with all areas
designated as photometry areas,
regardless of the individual enabled/
disabled photometry area states
configured in [ALC Area Selector].
Off: Operate ALC according to the
individual enabled/disabled
photometry area states configured in
[ALC Area Selector].
100
Set the minimum value for the ASC range.
13427
Set the maximum value for the ASC
range.
100
Set the minimum value for the AGC
range.
1600
Set the maximum value for the AGC
range.
4
Set the reaction speed for AGC/ASC.
These settings are also used for auto
exposure control.
Configure AWB settings.
Low Right
Select the area for which to configure
[AWB Area Enable].
False
Enable/disable the photometry area
selected in [AWB Area Selector].
False
On: Operate AWB with all areas
designated as photometry areas,
regardless of the individual enabled/
isabled states configured in [AWB
Area Selector].
Off: Operate AWB according to the
individual enabled/disabled
photometry area states configured in
[AWB Area Selector].
4
Set the AWB control speed. (8 is the
fastest.)
Idle
Display the AWB status.
Description