When The Full Image Plus The Vertical Ob Is Transmitted; When The Full Image Plus The Horizontal Ob Is Transmitted; Frame Rate Calculation In The Aoi Mode; Binning Control Setting : Off Or 2X1 (Binning Vertical=1) - IAI AM-200GE User Manual

2m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

7.2.2.2 When the full image plus the vertical OB is transmitted

Offset X=16(Note)
Offset Y=0
Width =1600
Height = Effective lines +4
Note: If the horizontal binning is x2, the value is 8.
7.2.2.3

When the full image plus the horizontal OB is transmitted

Offset X=0
Offset Y=4
Width =1632 (Note1)(Note2)
Height = Effective lines
Note1: When the horizontal OB is transferred, the width must be set at its maximum.
Note2: If the horizontal binning is used, the OB on both side is 8 and total 1616.

7.2.3 Frame rate calculation in the AOI mode

The frame rate in AOI mode depends on each setting of Offset, Height, Bit allocation
or Binning control. In the following formula, the part labelled (
decimal values rounded up.

7.2.3.1 Binning control setting : off or 2x1 (Binning Vertical=1)

In case of Offset Y < 4
Frame line number = ((1203 - (Height + (Offset Y - 4))) / 4)
In case of Offset Y ≧ 4
Frame line Number = (Offset Y / 4)
Frame rate (Hz) = 1/ (Frame line number x 0.00002004)
Setting examples (8-bit output)
Area
1/2
1/4
1/8
AM-200GE / AB-200GE
(Height - (4 – Offset Y)) + 29
roundup
+ Height + 28
Offset
Height
Continuous
Timed (EPS)
304
600
(Smearless OFF)
Trigger Width
Continuous
Timed (EPS)
454
300
(Smearless OFF)
Trigger Width
Continuous
528
150
Timed (EPS)
Trigger Width
+ ((1203 – (Height + (Offset Y - 4))) /4)
Frame rate
(fps)
64.05673
89.91026
112.8964
- 22 -
) has its
round up
+
rounddown
rounddown

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ab-200ge