Item
Pixel Format
Test Pattern
c) Acquisition Control
Acquisition Mode
Acquisition Start
Acquisition Stop
Acquisition Frame Count
Acquisition Frame Rate (Hz)
Trigger Selector
Trigger Mode
Trigger Software
Trigger Source
Trigger Activation
Trigger OverLap
Exposure Mode
Exposure Time
Exposure Auto
Setting range
GO-5100M-USB:
8 Bit Monochrome,
10 Bit Monochrome,
10 Bit Monochrome
Packed,
12 Bit Monochrome,
12 Bit Monochrome
Packed
GO-5100C-USB:
8 Bit Bayer RG,
10 Bit Bayer RG
(Unpacked),
10 Bit Bayer RG Packed,
12 Bit Bayer RG
(Unpacked),
12 Bit Bayer RG Packed
GO-5100M-USB:
Off,
GreyHorizontal
Ramp,
GreyVertical
Ramp,
GreyHorizontalRamp
Moving
GO-5100C-USB:
Off,
GreyHorizontalRamp,
GreyVerticalRamp,
GreyHorizontalRamp
Moving,
HorizontalColorBar,
VerticalColorBar,
MovingColorBar
Single Frame,
Multi Frame,
Continuous
1 to 255
0.125 to 74.0192 (Full)
Acquisition Start,
Acquisition End, Frame Start,
Acquisition Transfer Start
Off, On
Low,
High,
Software,
Pulse Generator 0,
User Output 0,
User Output 1,
Line 5 - Optical In 1,
NAND0 Out,
NAND1 Out
Rising Edge,
Falling Edge
Off,
Read Out
Off,
Timed,
Trigger Width
8-bit: 7 to 7999920
10/12 bit: 8 to 7999900
Off, Continuous
— 49 —
GO-5100M-USB / GO-5100C-USB
Default value
GO-5100M-USB:
Set the pixel format.
8 Bit
[12 Bit Monochrome] and [12 Bit
Monochrome
BayerRG] are enabled when [Video
GO-5100C-USB :
Process Bypass] is set to [On].
8 Bit BayerRG
Off
Select the test image.
Configure image acquisition settings.
Continuous
Select the image acquisition mode.
Start image acquisition.
Stop image acquisition.
1
In [Multi Frame] mode, set the number of
frames to acquire.
74.0192
Set the frame rate as a frequency. (unit: Hz)
The maximum value varies depending on
the TapGeometory and ROI settings.
Frame Start
Select the trigger operation.
Off
Select the trigger mode.
Execute a software trigger.
Line 5 - Optical
Select the trigger signal source.
In 1
Rising Edge
Select the polarity of the trigger signal
(rising edge of
(i.e., location of signal at which trigger is
input signal)
applied).
Read Out
Select the trigger overlap operation.
Timed (control
Select the exposure mode.
via exposure
time)
13427
Set the exposure time.
Off
Set whether to enable auto exposure.
Description