Item
Pulse Generator Length
Pulse Generator Length
(ms)
Pulse Generator Frequency
(Hz)
Pulse Generator Start Point
Pulse Generator Start Point
(ms)
Pulse Generator End Point
Pulse Generator End Point
(ms)
Pulse Generator Pulse-
Width (ms)
Pulse Generator Repeat
Count
Pulse Generator Clear
Activation
Pulse Generator Clear
Source
Pulse Generator Clear
Inverter
Pulse Generator Clear
Sync Mode
m) JAI Custom Control ALC
ALC Reference
Setting range
1 to 1048575
0.00222222 to 2330.17
0.429154 to 450000
0 to 1048574
0 to 2330.164444
1 to 1048575
0.002222 to 2330.166666
0.002222 to 2330.166666
0 to 255
Off,
High Level,
Low Level,
Rising Edge,
Falling Edge
Low,
High,
Acquisition Trigger Wait,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL,
LVAL,
User Output 0,
User Output 1,
Line5 - Opt In 1,
Nand0 Out,
Nand1 Out
True, False
Async Mode,
Sync Mode
10 to 95
— 53 —
GO-5100M-USB / GO-5100C-USB
Default value
30000
Set the maximum count up value using
clock value.
66.6667
Set the maximum count up value using
ms.
This value is calculated based on the
Pulse Generator Length value.
The setting range varies depending on
the Clock Pre-Scaler value.
15
Set the maximum count up value using
frequency.
This value is calculated based on the
Pulse Generator Length value.
0
Set the start point for the High interval
using clock value.
When the counter reaches this value, the
output becomes 1.
0
Set the start point for the High interval
using ms.
When the counter reaches this value, the
output becomes 1.
The setting range varies depending on
the Clock Pre-Scaler value.
15000
Set the start point for the Low interval
using clock value.
When the counter reaches this value, the
output becomes 0.
33.3333
Set the start point for the Low interval
using ms.
When the counter reaches this value, the
output becomes 0.
The setting range varies depending on
the Clock Pre-Scaler value.
33.3333
Display High interval width for the pulse in
ms.
This is a calculation of the time between
the Start Point and End Point.
The setting range varies depending on
the Clock Pre-Scaler value.
0
Set the repeat count for the counter.
When this is set to 0, the counter will be
free-running with limitless repeating.
0: Off
Set the clear signal condition for the
count clear input of the pulse generator.
0: Low
Select the count clear input signal source.
Line4 TTL In is available on Standard
Model.
False
Select whether to invert the polarity of the
count clear input signal.
Async Mode
Select the sync mode for the count clear
input signal.
Configure JAI ALC settings. These
settings are also used for AGC (auto gain
control).
50
Set the target level for ALC. (unit: %)