2.4

Power Cable

Connect the power cable (FRU-3P-FF-A002M-000, 2m, supplied) to the connector.
When connecting the power supply, connect the positive and negative terminals cor-
rectly.
Note: Turn off the power at the switchboard before beginning the connection.
Ground wire
Connect the ground wire (IV-8sq, local supply) to the ground terminal on the rear panel
with the crimp terminal.
2.5

MULTI Cable

Use the MULTI cable for the NMEA0183 equipment, external buzzer, event switch and
power switch. The connector has 9 wires and a connector (SMP-11V). Use the table
below for reference when connecting the MULTI cable.
Wire color
White
Blue
Gray
Red
Orange
Black
Purple
Brown
Black
2.5.1
How to set up NMEA0183 data output
Note: To set up data input from NMEA0183 equipment, see "NMEA0183 equipment
data input" on page 2-6.
1. Tap the [Home] icon (
settings.
2. Tap [Settings], then scroll the menu to show [Initial Setup]. Tap [Initial Setup].
3. Scroll the menu to show [NMEA0183 Output], then tap [NMEA0183 Output].
4. Tap [Baud Rate] to set the output baud rate. Available options are [4,800], [9,600]
and [38,400].
5. Tap the appropriate setting then tap the
6. Tap [NMEA-0183 Version] to set the version. Available options are [1.5], [2.0] and
[3.0].
7. Tap the appropriate setting then tap the
8. Select the appropriate sentences to output, then tap the flipswitch to set the
sentence to [ON].
9. Tap the [Close] icon at the top right of the screen to close the menus.
Function
Pin No.
NMEA-TD-A
1
NMEA-TD-B
2
EXT_BUZZER
3
+12 V
4
EVENT_SW
5
GND
6
POWER_SW
7
DC_N
8
DRAIN
11
) to show the home screen and display mode
Remark (Port No.)
NMEA0183 Output
External buzzer ON/OFF
External buzzer power (12 V)
Event switch (MOB, etc.)
Grounding
Power switch
Grounding
icon.