11.2 Mounting Procedure

Part Number
667/CI/47235/000

Table 11 : Pole Mounting Kit Document Reference

To mount the repeater the following instructions are provided;
1. Feed the clamp band through the square ball plate using the custom clamp holes
until the square ball plate is in the centre of the band.
2. Clean the area of the pole that will meet the ball plate. Remove the double stick
tape cover from the back of the plate, wrap the clamp band around the pole and
feed into the fastener. Tighten the clamp to secure it.
3. Attach the double socket arm to the ball plate.
4. Attach the repeater to the double socket arm.
5. Orientate the repeater in the direction depicted within the junction drawing and
tighten the double socket arm to secure.
Note: In cases where the repeater is to be mounted on a traffic signal pole, the
access point L-bracket (667/1/47230/000) can be used and the repeater is to be
mounted as described in section 10.1 and 10.1.1 above.