Final Access Point Configuration; Figure 38 : Setting The Transmit Interval - Siemens 667/HB/47200/000 Manual

Wimag vehicle detection system general handbook
Table of Contents

Advertisement

7.3.4

Final Access Point Configuration

1. If required the Access Point radio frequency channel can be selected within the AP
Config - Radio tab of the Access Point Config Window.
2. Setting the frame rate: The communications frame rate can be set by going to the 'AP
Config' screen. Select the 'Event' sub-tab. Adjust the 'Transmit Interval' to 0.0625s
(below example shows 0.125s).
3. The 'Extra Latency' should also be set to '0.125 sec' while the user is on the 'Event'
tab. This will add a latency to the detection system but ensures the system has
sufficient time to utilise the 'detection timestamp's reported by the sensors.
4. Setting the timeout period: The detection timeout (retune) is to be set at 4 minutes as
default. This is set by going to the 'AP Config' screen. Select the 'Detection' sub-tab.
Adjust the 'Count Recalibrate Timeout' to 4 minutes. This timing can be adjusted
depending on application requirement.
1
This value should be set to 0.125s if tandem repeaters are to be used. This is a restriction of the
system.
Version
11
Last Editor
Jeerh, Manpreet
Document
WIMAG GENERAL HANDBOOK
Name
Copyright © Siemens Mobility Limited 2012. All Rights Reserved.
1

Figure 38 : Setting the Transmit Interval

Page 52 of 117
Siemens Mobility Limited
Sopers Lane, Poole, Dorset
Status
Issued
Date
March 2020
Doc. No.
667/HB/47200/000
BH17 7ER