System Elements - Wimag Loop Detector Replacement Card; Figure 21 : Wimag Loop Detector Replacement Card - Siemens 667/HB/47200/000 Manual

Wimag vehicle detection system general handbook
Table of Contents

Advertisement

5 System Elements - WiMag Loop Detector
Replacement Card

Figure 21 : WiMag Loop Detector Replacement Card

Siemens Part Number
Input Voltage
Power Supply
Dimensions
Weight
Environmental
Operating Temp.
Detector Interface
Note: The power at the backplane must be derived from an appropriate power
supply (e.g. 50VA LV Detector Transformer Kit, 667/1/27853/000 – other options
are available : reference section 19 for details).
The Loop Detector Replacement Card is a direct WiMag replacement version of a loop
detector card. The Loop Detector Replacement Card uses a standard detector backplane
and will therefore allow the controller to interface with up to four wireless sensors.
The Loop Detector Replacement Card provides a bridge between the Sensys equipment
(access point, repeater and sensor) and the traffic controller and may be used as a direct
replacement for loop detector cards.
Version
11
Last Editor
Jeerh, Manpreet
Document
WIMAG GENERAL HANDBOOK
Name
Copyright © Siemens Mobility Limited 2012. All Rights Reserved.
667/1/47280/000
24VDC and 24VAC
5.7W (236mA at 24VDC) not including access point
loading
13.4 cm x 10.6 cm x 13.5 cm
• 0.1 kg
• designed for roadside cabinet installation
-25ºC to +70ºC
4 sensors (solid state relays)
Page 32 of 117
Status
Date
Doc. No.
Siemens Mobility Limited
Sopers Lane, Poole, Dorset
BH17 7ER
Issued
March 2020
667/HB/47200/000