Creating A Raid 0 Array In Uefi Mode - Inspur 3408 Series Configuration Manual

Table of Contents

Advertisement

The drives in a RAID array shall be of the same type and specifications.
Procedures:
1.
Configure the UEFI mode and re-enter BIOS configuration screen.
2.
Log in to LSI SAS3508 management screen, switch to Advanced tab, select the
LSI SAS3508 controller from the existing RAID controller card list, and press
<Enter>.

3.3.1 Creating a RAID 0 Array in UEFI Mode

1.
On the popup screen, select Configuration Management and press <Enter>.
Figure 3-5 Selecting Configuration Management
On the popup screen, select Create Virtual Drive and press <Enter>.
2.
Figure 3-6 Selecting Create Virtual Drive
Select Select RAID Level by pressing <↑> or <↓> and press <Enter>.
3.
4.
Select RAID 0 from the list and press <Enter>.
Locate Select Drives by pressing <↑> or <↓> and press <Enter> to add member
5.
drives.
19