Inspur 3408 Series Configuration Manual page 48

Table of Contents

Advertisement

8.
On the popup screen, select required options by pressing <↑> or <↓> to
configure the RAID controller card parameters.
Note: This RAID array contains 4 SDDs, without any battery capacitor. After
parameter setting is completed, select Save Configuration and press <Enter>.
Figure 3-37 Parameter Configurations
The following table lists parameters and descriptions of advanced RAID properties.
Table 3-9 Parameters and Descriptions of Advanced RAID Properties
Parameter
Virtual Drive
Name
Virtual Drive Size
Virtual Drive Size
Unit
Strip Size
Read Policy
Description
Name of a virtual drive.
Capacity of a virtual drive, which is the maximum capacity
supported by the current RAID array by default.
Capacity unit.
Size of strip data on each drive. For Inspur 3508MR, the strip
size can be 64 K, 128 K, 256 K (recommended), 512 K, and 1
M. The strip size of 3408iMR can only be 64 K.
Read policy of virtual drives, including:
No Read Ahead: Read Ahead disabled.
Read Ahead: Read Ahead enabled. The controller can
43