Run and Auto Reset Modes
Run mode is the normal operating state of the NIC. Auto Reset
mode is entered when the watchdog timer is triggered and the Print
Server resets itself. In either mode, the STAT LED flashes at a
varying rate, depending on whether the unit IP address is
configured. The Run Mode and Auto Reset Mode indicator
descriptions are given in Table 1.
Table 1. Run Mode and Auto Reset Mode Indicator Descriptions
STAT
Indication
OFF
flashes on once per second
OFF
flashes on two times per
second
ON
flashes off once per second
ON
flashes off twice per second
Network Indicator
The NET LED displays the status of the network link. When the
NET LED is on, link integrity is confirmed. The NET LED flashes off
for 1/3 second when a data packet is being transferred. When the
NET LED is off, the network connection has been severed.
NET
Indication
ON
constantly
ON
flashes off 1/3 second
Normal Mode, IP address configured
IP address not configured
Download (MOS)
Error
Table 2. NET LED Indicator
Indicates link integrity
Flashes off 1/3 second each time a
packet is transmitted
10/100Base-T
Description
Description
25