Tst 5000 Mv Syn - Fronius TransSteel 3500 Syn Operating Instructions Manual

Hide thumbs Also See for TransSteel 3500 Syn:
Table of Contents

Advertisement

TSt 5000 MV
Mains voltage (U
Syn
Max. effective primary current (I
Max. primary current (I
Mains fuse protection
Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Mains fuse protection
Mains voltage tolerance
Grid frequency
Cos phi (1)
Max. permissible mains impedance Z
Recommended earth-leakage circuit break-
er
Welding current range (I
Welding current at
U
Welding current at
U
Output voltage range according
to standard characteristic (U
Open circuit voltage (U
Apparent power
Degree of protection
Type of cooling
Insulation class
Overvoltage category
Pollution level according to IEC60664
Safety symbols
Dimensions l x w x h
Weight
Max. noise emission (L
Idle state power consumption at 400 V
Power source efficiency at 500 A / 40 V
126
)
1
1max
)
1
1max
10 min / 40 °C (104
°F)
: 200 V
1
10 min / 40 °C (104
°F)
: 208 - 460 V
1
0
at 200 V AC / 500 A / 40 % ED
at 400 V AC / 500 A / 40 % ED
WA
)
1eff
)
)
1eff
)
on PCC
max
)
MIG / MAG
2
Rod electrode
MIG / MAG
)
2
Rod electrode
peak / U
r.m.s)
0
)
3 x
200 V
39.5 A
66.7 A
63 A slow-blow
3 x
400 V
20.6 A
32.5 A
35 A slow-blow
-10 / +15%
50 / 60 Hz
1)
63 mOhm
10 - 500 A
10 - 500 A
35%
60%
500 A
420 A
40%
60%
500 A
420 A
14.3 - 39 V
20.2 - 40 V
23,08 kVA
2)
22,49 kVA
2)
S, CE, CSA
747 x 300 x 497 mm
29.4 x 11.8 x 19.6 in.
43.6 kg / 96.1 lb.
75 dB (A)
230 V
36.3 A
57.4 A
460 V
18.1 A
28.6 A
0.99
Type B
100%
360 A
100%
360 A
57 V
IP 23
AF
B
III
3
82,7 W
90 %