Mitsubishi Electric MELSEC-Q Series User Manual page 44

Simple motion module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

(3) Transient transmission
Function
Communications within the same
network
(4) Diagnostic functions
Function
CC-Link IE Field Network diagnostics
Module error collection function
(5) Other functions
Function
Reserved station specification
Temporary cancel of the reserved
station setting
Interrupt request to a CPU module
Transient transmission is performed to other stations using dedicated
instructions and GX Works2.
The status of CC-Link IE Field Network can be checked using GX Works2.
The error locations, error causes, corrective actions, and event history can be
checked in GX Works2.
The error information occurred in the Simple Motion module is notified and
accumulated. Then, the confirmation of error information and troubleshooting
can be executed using GX Works2.
The reserved stations are included in the number of stations that will be
connected to the network in the future without actually connecting them.
Reserved stations are not detected as faulty stations even though they are
not actually connected.
Reserved station specification can be temporarily cancelled without changing
the parameters.
Interrupt conditions are checked every link scan, and if the interrupt
conditions are met, an interrupt request is made to the CPU module to start
the interrupt program.
Description
Description
Description
3 - 4
Chapter 3 SPECIFICATIONS
Reference
Chapter 10
Reference
Chapter 9
Section 12.2
Reference
Section 8.5
Section 9.6
Section 7.7
Section 8.6

Advertisement

Table of Contents
loading

Table of Contents