Mitsubishi Electric MELSEC-Q Series User Manual page 126

Simple motion module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Item
Selected Station Communication
Status Monitor
[Communication
Test...] button
[IP Communication
Test...] button
Operation Test
[Cable Test...]
button
[Link Start/Stop...]
button
[Network Event
History...] button
[Reserved Station
Information
Function Enable...]
Confirmation/Set
button
[Enable/Disable
Ignore Station
Errors...] button
[System Monitor...]
button
Selected Station
Operation
[Remote
Operation...] button
Chapter 9 CC-LINK IE FIELD NETWORK DIAGNOSTICS
Sets a station number for a slave station to which a station number has not been set.
This button is displayed only when a slave station meeting the following conditions has
been selected in "Network Status".
• The slave station supports station number setting from the master station.
• A station number has not been set to the slave station.
4)
When a station set in "Network Configuration Settings" is added, the external device
connected to the slave station outputs data input from the master station, simultaneously
with configuration of the station number setting. Therefore, set the CPU module to STOP or
check that outputs from the external device will not cause a problem beforehand.
Click this button to check error details. Take corrective actions, following description
5)
displayed in "Error Factor" and "Troubleshooting".
Displays the LED status of a module and communication status of PORT1 and PORT2.
6)
(Refer to Chapter 2.)
Displays status of the cables connected to PORT1 and PORT2.
7)
Displays the information of the extension module connected to the remote device station.
8)
(Note-2)
(Note-1): For how to clear the station number set for a slave station in the CC-Link IE Field
Network diagnostics, refer to the manuals for modules used on slave stations.
(Note-2): To display the information of an extension module, a Simple Motion module with a serial
number (first five digits) of "15092" or later is required.
This item cannot be set for the Simple Motion module.
This item cannot be set for the Simple Motion module.
This item cannot be set for the Simple Motion module.
Starts or stops cyclic transmission. (Refer to Section 9.4.)
Displays event history of a network. (Refer to Section 9.5.)
Temporarily cancels a reservation for a slave station or reserves the slave station again. (Refer to
Section 9.6.)
This item cannot be set for the Simple Motion module.
Displays the System Monitor window. (Refer to Section 12.2.)
Performs the remote operations (RESET operation only) to the CPU module. (Refer to Section
9.7.)
9 - 14
Description
(Note-1)
: Properly connected
: Error (cable disconnection)
: Error (other than cable disconnection)