(1) Setting data
Setting data
Own station's network No. (1 to 239, 254)
Jn
254: Network specified in Valid Module During Other
Station Access
Start I/O number of the Simple Motion module of the own
station
Un
(00 to FEH: Upper 2 digits of the I/O number expressed in
3 digits)
(S1)
Start device of the own station where control data is stored
Start device of the own station where data to be written is
(S2)
stored
Start device of the target station where data is to be written
(D1)
(A continuous area with the write data length is required.)
Device of the own station, which is turned on for 1 scan
(D2)
upon completion of the instruction.
(D2)+1 is turned on as well when the instruction fails.
Device of the target station, which is turned on for 1 scan
(D3)
upon completion of the instruction.
(Data writing from another station can be confirmed.)
(a)
Control data
The control data of the SWRITE instruction control data is the same as that of the
WRITE instruction. (Refer to Section 10.6.)
(b)
Start device of the own station where data to be written is stored
The start device of the own station where data to be written by the SWRITE
instruction is stored is the same as that of the WRITE instruction. (Refer to
Section 10.6.)
(c)
Start device of the target station where data is to be written
The start device of the target station where data is to be written by the SWRITE
instruction is the same as that of the WRITE instruction. (Refer to Section 10.6.)
Chapter 10 DEDICATED INSTRUCTIONS
Description
10 - 34
Set by
Data type
16-bit binary
User
Device name
System
Bit