Introduction
The RocketLinx ES8108 and ES8108F series of industrial Ethernet switches conform to
IEE802.3 and 802.3u standards. This series includes the following models:
ES8108 supports eight 10/100BASE-TX ports
ES8108F-M (Multi-Mode) supports six 10/100BASE-TX and two 100BASE-FX fiber ports
ES8108F-S (Single-Mode) supports six 10/100BASE-TX and two 100BASE-FX fiber ports
The ES8108/ES8108F feature an IP31 rated compact metal housing for operation in harsh
environments. The series also features an alarm relay output to notify users of a port link or
power failure that can be enabled or disabled using the 9-pin DIP switch. The ES8108/8108F
can be powered using a wide input power range of 10-60VDC using the 6-pin terminal block.
See the Comtrol website for complete product specifications.

Wiring the Power Inputs

The ES8108/ES8108F provides:
Power redundancy and reverse polarity protection (PW1/PW2). If both power inputs are
connected, the ES8108/ES8108F is powered from the highest connected voltage.
Positive or negative power source. If using redundant power supplies, they must be in
the same mode.
An alarm if PW1 or PW2 are no longer receiving power.
Use this procedure to wire the power:
1. Insert the positive and negative wires into the + and - contacts on the PW1 or PW2 on the
terminal block connector.
2. Tighten the wire-clamp screws to prevent the wires from being loosened.
Note: Power should be disconnected from the power supply before connecting it to the
switch. Otherwise, your screwdriver blade can inadvertently short your terminal
connections to the grounded enclosure.