Led Indicators - Comtrol ROCKETLINX ES8108 Quick Installation Manual

Hide thumbs Also See for ROCKETLINX ES8108:
Table of Contents

Advertisement

Optical Fiber Cable Attenuation
Fiber Type
Wavelength
Mul -Mode
850nm
50/125um
1310mm
Mul -Mode
850nm
62.5/125um
1310nm
Single-Mode
1310nm
9/125um
Single-Mode
1550nm
9/125um
* These values are per TIA/EIA and other industrial specifications.
** These values are one example of the performance that can be obtained with a new fiber
installation.

LED Indicators

There are system diagnostic and Ethernet port LEDs located on the front panel of the
ES8108/ES8108F.
PWR 1/PWR2
Alm (Alarm)
Port 1- 8
(ES8108)
Port 1- 6
(ES8108F-S or
ES8105F-M)
Fiber Ports 7- 8
(ES8108F)
A enua on/km *
3.5dBm
1.5dBm
3.5dBm
1.5dBm
0.4dBm
0.3dBm
LED
LED Lit
Powered
Port link is down or a power
failure event has occurred.
A green lit LED indicates that a
network device is detected and
linked up.
A yellow lit LED indicates that a
network device is detected and
link established at 100Mbps.
A green lit LED indicates that a
network device is detected and
a link has been established at
100Mbps.
A enua on/km **
2.5dBm
0.8dBm
3.0dBm
0.7dBm
0.35dBm
0.22dBm
LED Off
No power
Not ac vated
If the green Link LED is lit and the
yellow speed LED is off, a network
device is detected and a link has
been established at 10Mbps.
Both green and yellow LEDs are not
lit a port link has not been
established.
No ac ve link
6
Connector Loss
Splice loss
0.75dBm
0.1dBm
0.75dBm
0.1dBm
0.75dBm
0.1dBm
0.75dBm
0.1dBm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rocketlinx es8108f

Table of Contents