Grounding RocketLinx ES8108/ES8108F
There is an earth ground screw on the
bottom side of the RocketLinx
ES8108/ES8108F. Connect the
earth ground screw of the switch to a
grounding surface to ensure safety
and prevent noise.
Wiring the Power Inputs
The RocketLinx ES8108/ES8108F provides redundant DC power input.
1. Insert the positive and negative wires into the + and - contact either under the PW1 or
PW2 on the terminal block connector.
2. Tighten the wire-clamp screws to prevent the wires from
being loosened.
Note: The recommended working voltage is 24VDC (12-48VDC).
RocketLinx ES8108 / ES8108F chassis
Ground should connect with Earth
Ground
Bottom side of
RocketLinx ES8108
RocketLinx ES8108F
Dry Relay Output
PWR 2
PWR 1
12 - 24AWG Wire
12 - 24AWG Wire
Earth Ground
Screw
Earth Ground
Warning: Do not connect to AC line – Neutral
DC Power output
DC 12V - 48V
DC Power output
DC 12V - 48V
2
Alm
PW1
PW2
Alarm Control
port 1~8
V-
V+
AC/DC Power Supply
(DC 12V - 48V, 1A:UL Listed)
AC Power input
AC/DC Power Supply
(DC 12V - 48V, 1A:UL Listed)
AC Power input
power
V-
V+
Earth Ground
Earth Ground