The following table gives the 1st level functions and the single settable parameters.
= DEFAULT value set in factory.
Par
Function
Selects the functio-

ning logic. (see notes
after the table)
Close input confi gu-

ration (see notes after
the table)

Photocells

Encoder

Encoder sensitivity

Warning fl ash

Arm and head lights
Pause time (expres-

sed in seconds)

Arm lights brightness
Control unit
9.2
1ST
LEVEL PROGRAMMING
: Hold-to-run
: Semi automatic
: Automatic
: Standard close input
: Close-when-released input
: The close command acts as a release closing and safety function.
: When closing it stops and waits for disengaged photocell commands
: When closing it stops; reclosing after 1'' when the photocell is disengaged
: When closing it reopens; reclosing after 1'' when the photocell is disengaged
: When closing it reopens; reclosing after 5'' when the photocell is disengaged
: When closing it reopens; reclosing when the photocell is disengaged and
resets the eventual pause time
: When closing it reopens and waits for disengaged photocell commands
: Excluded
: When closing it stops and waits for commands
: When closing it reopens and waits for commands
: When closing it reopens, reclosing after 5 seconds
 (minor - major obstacle sensitivity)
: Excluded
: Before each movement on a confi gured output (see parameters ,,, in
the 2nd level table)
: Before each movement on a confi gured output and on the boom lights
: When moving fl ashing red light, when the boom is closed and open off red
light.
: When moving fl ashing red light, when the boom is closed and off when the
boom is open on red light.
: When moving and with the boom closed fl ashing red light, when stopped and
on red light when the boom is open on red light.
: When moving fl ashing red light, when the boom is closed and on green light
when the boom is open off red light.
: When moving fl ashing red light, when the boom is closed and on green light
when the boom is open on red light.
-
: 40%
: 60%
: 80%
: 100%
= parameter value set during installation: must be indicated if
DEFAULT value is modifi ed.
Settable data
- 25 -