Serial Ports; System Latency; Physical; Electrical - evertz HD9010TM Instruction Manual

Table of Contents

Advertisement

HD9010TM High Definition Time Code Master Manual

4.1.6. Serial Ports

Standard:
RS-232
Number:
2 ports
Baud Rate:
COM1:
115,200 baud (57600 for Rev 1 hardware) for firmware upgrades
Programmable for data broadcast applications
AUX COM:
Programmable
Connectors:
9 pin female "D"
Control:
COM1:
Firmware upgrades, time code data broadcast
AUX COM:
Programmable - future use

4.1.7. System Latency

Input to output Delay:
Approx. 1.8 μsec (136 samples)
Ref:Input:
Ref: Bi-Level:
up to 1 HD line
Ref: Tri-Level:
up to 1 HD line

4.1.8. Physical

Dimensions:
19" W x 1.75" H x 18.75" D.
(483mm W x 45mm H x 477mm D)
Weight:
8 lbs. (3.5Kg)

4.1.9. Electrical

Auto ranging, 100  240 VAC, 50/60 Hz 40 Watts.
Power:
Safety:
ETL listed.
Complies with EU safety directive
EMI/RFI:
Complies with FCC Part 15 Class A,
EU EMC Directive
4.2.

UPGRADING THE FIRMWARE

4.2.1. Overview

The firmware in the HD9010TM is contained on a FLASH EPROM. From time to time firmware updates
will be provided to add additional features to the unit. There are two different versions of hardware that may
be installed in the HD9010TM. The HARDWARE VERSION menu item will tell you whether you have Rev
1 (7700PB3) or Rev 2 (7700PH4) hardware installed.
differently for the different revisions of the hardware.
You will need the following equipment in order to update the Firmware:
PC with available communications port.
therefore a 486 PC or better with a 16550 UART based communications port is recommended.
"Straight-thru" serial extension cable (DB9 female to DB9 male) or (DB25 female to DB9 male).
Terminal program that is capable of Xmodem file transfer protocol. (such as HyperTerminal)
New firmware supplied by Evertz.
Page 4-2
The baud rate for upgrading firmware is set
The communication speed is 57600 or 115200 baud,
Revision 2.4.1
TECHNICAL DESCRIPTION