3.1.9. An Overview of the Status Indicators

There are 15 status indicators located on the front panel that show operational status of the HD9010TM
at a glance.
PANEL LOCK
This green LED indicates that the Front Panel is locked against accidental
changes.
GEN
This green LED indicates that the GENERATOR SETUP menu mode is active.
RDR
This green LED indicates that the READER SETUP menu mode is active.
VCG
This green LED indicates that the VCG SETUP menu mode is active.
UTIL
This green LED indicates that the UTILITY SETUP menu mode is active.
DISPLAY This green LED indicates that the Normal front panel display mode is active.
PSU STATUS 1, 2
These green LEDs indicate that the corresponding power supply is functioning
normally. On units fitted with a single power supply the PSU STATUS 2 LED will be Off all
the time.
VIDEO
This green LED indicates that valid video signal is present.
GENLOCK
This green LED indicates that a valid genlock reference is present and the HD9010TM
has locked to it.
JAM
This green LED indicates that continuous jam sync mode is active.
ANC
This green LED indicates that RP188 ancillary timecode is present on the video input.
LTC 1
This green LED indicates that linear timecode is present on the LTC input.
LTC 2
This green LED indicates that linear timecode is present on the AUX LTC input.
ANC GEN This green LED indicates that RP188 ancillary timecode is being inserted on the video
output.
BYPASS This green LED indicates that optional bypass relay is active. The HD video input is directly
connected to the HD BYPASS output and the HD9010TM will have no effect on the video
signal.